Wayne-Dalton 3651-372 Stud Sensor User Manual


 
After installing the opener, the door must reverse when
it: contacts a 1-1/2" high object (or a 2 x 4 board laid
flat) on the floor. To verify proper operation:
1. Using the wallstation, activate the door to the fully
open position .
2. Place a 2 x 4 board laid flat on the garage floor under
the door path.
3. Activate the door to the closed position with the wallstation. Upon contacting the 2 x 4 board, the door should
stop, then reverse direction within two seconds and travel to the full open position. If the door does not respond
to the required tests, repeat install routine making sure the door is in the fully closed position prior to activation.
If problem persists contact Wayne Dalton Customer Service (888) 827-3667
WARNING IF OPENER DOES NOT RESPOND PROPERLY AND FAILS EITHER OF THE
TWO TESTS (STEP 21 AND 22), DOOR MAY CAUSE A SEVERE OR FATAL INJURY. HAVE A QUALIFIED
SERVICE PERSON MAKE NECESSARY REPAIRS.
Starting with the door in the fully open position, place a 6" high object on the floor progressively one foot from
the left side of the door, center of door and one foot from the right side of the door. In each position, activation
of the opener with the wallstation up/down button should cause the door to move no more than one foot, stop
and then reverse to fully open position.
The same 6" high object when placed on the floor, while door is closing, should also cause the door to reverse.
WARNING WHEN PERFORMING THIS PART OF THE TEST, DO NOT PLACE YOURSELF
UNDER DESCENDING DOOR, OR
SEVERE OR FATAL INJURY MAY
RESULT.
WARNING IF THE OPENER
DOES NOT RESPOND PROPERLY, OR
FAILS THESE TEST, HAVE A
QUALIFIED SERVICE PERSON MAKE
NECESSARY ADJUSTMENTS/REPAIRS.
FAILURE TO MAKE ADJUSTMENTS
COULD RESULT IN SEVERE OR FATAL
INJURY.
24
Step 21: Photoelectric Obstruction Sensor Test
12”
6”
12”
Step 22: Contact Obstruction Test
CENTER OF
DOOR
2 X 4 LAID FLAT
ON FLOOR