Agilent Technologies Agilent 81130A 400 Welding System User Manual


 
100
Specifications
Agilent 81130A Specifications
Width
The width can be entered as absolute width, duty cycle, or trailing edge
delay.
Delay
Measured between trigger output and main output. Can be entered as
absolute delay, phase ° or % of period.
Width
Agilent 81130A with
Agilent 81131A
Agilent 81130A with
Agilent 81132A
Width range: 1.25 ns to (period  1.25 ns) 750 ps to (period  750 ps)
Resolution: 4 digits, 2 ps best case [0.05% of period]
Accuracy:
±
100 ppm
±
200 ps [
±
0.06% of period]
Jitter: 0.001%
+
15 ps
Delay
Agilent 81130A with
Agilent 81131A
Agilent 81130A with
Agilent 81132A
Variable delay range: 0 to 3.00 µs: independent of period
> 3.00 µs: 0 ns to 1 period
Resolution: 4 digits, 2 ps best case [0.05% of period]
Accuracy:
±
(0.01% + 100 ps) relative to the zero-delay
[±0.035% of period]
Jitter: 0.001% + 15 ps
Fixed Delay: 32 ns typ.