SCPI Instrument Command List
Command
:DIG:PATT:LOOP:LENG
Long
:DIGital[:STIMulus]:PATTern:LOOP[:LEVel[1]]:LENGth
Form
Set & Query
Parameter
1 | 2 | 3 | 4
*RST value
1
Description
Use this command to set the number of segments to be repeated within
the counted loop.
Example
See previous example (page 47).
Command
:DIG:PATT
Long
:DIGital[:STIMulus]:PATTern[:STATe]
Form
Set & query
Parameter
ON | OFF | 1 | 0
*RST value
OFF
Description
Use this command to enable and disable PATTERN mode.
Command
:DIG:PATT:PRBS
Long
:DIGital[:STIMulus]:PATTern:PRBS
Form
Set & Query
Parameter
Numeric
*RST value
7
Specified Limits
7 to 15 (integer)
Description
Use this command to set up PRBS polynom for all PRBS segments on all
channels.