Fujitsu CM71-00329-7E Biscuit Joiner User Manual


 
139
CHAPTER2 Dependence Functions
2.3.8.2 Displaying Performance Measurement Data
Display the measured time and measuring count by using the SHOW PERFORMANCE
command.
Displaying Measured Time
To display the time measured, specify the starting event number or the ending event number.
>SHOW PERFORMANCE/TIME 1,9000,18999,1000
event = 1 -> 2
min time = 11637.0
max time = 17745.0
avr time = 14538.0
total
count
0
0
0
2
19
52
283
92
3
1
0
0
452
0.0 -
9000.0 -
10000.0 -
11000.0 -
12000.0 -
13000.0 -
14000.0 -
15000.0 -
16000.0 -
17000.0 -
18000.0 -
19000.0 -
8999.0
9999.0
10999.0
11999.0
12999.0
13999.0
14999.0
15999.0
16999.0
17999.0
18999.0
>SHOW PERFORMANCE/TIME 1,13000,16999,500
event = 1 -> 2
min time = 11637.0
max time = 17745.0
avr time = 14538.0
Total measuring count
Lower time limit for display
Upper time limit for display
Minimum
execution time
Maximum
execution time
Average
execution time
Event number
Count of measuring within given time interval
total
count
21
13
39
121
162
76
16
2
1
1
452
0.0 -
13000.0 -
13500.0 -
14000.0 -
14500.0 -
15000.0 -
15500.0 -
16000.0 -
16500.0 -
17000.0 -
12499.0
13499.0
13999.0
14499.0
14999.0
15499.0
15999.0
16499.0
16999.0
17499.0
The lower time limit, upper time limit and display interval can be specified. The specified time v
TIMERSCALE command, and in 100 ns when
the minimum is set to 100 ns.