Grizzly g0746 Lathe User Manual


 
-28-
Model G0746/G0749 (Mfg. Since 3/13)
To connect lathe to power:
1. Make sure the main power switch on the
lathe electrical cabinet is turned to the OFF
position, then open the door.
2. Insert the incoming power wires through the
opening shown in Figure 23.
Figure 23. Location of opening in electrical
cabinet for incoming power.
Opening for
Incoming Power
3. Connect the incoming hot wires to the L1,
L2, and L3 terminals, shown in Figure 24.
Connect the incoming ground to the ground-
ing terminal (PE).
4. Make sure the wires have enough slack so
they are not pulled tight or stretched.
5. Close the main electrical cabinet door.
Figure 24. Location to connect incoming hot
wires and ground wire.
L3 L2 L1 PE
Once the assembly is complete, test run your
machine to make sure it runs properly and is
ready for regular operation.
The test run consists of verifying:
The motor powers up and runs correctly.
The motor turns in the correct direction
(machine is not wired out of phase).
The safety features work correctly.
The brake system works correctly.
The coolant system works correctly.
If you notice an unusual noise or vibration, stop
using the machine immediately, and remedy
before operating it further.
Te s t Ru n
Before starting the lathe, make sure you
have performed the preceding assembly
and adjustment instructions, and you have
read all the documentation provided with the
lathe and are familiar with the various func-
tions and safety features on this machine.
Failure to follow this warning could result in
serious personal injury or even death!
Figure 25. Location of the main power switch.
Main Power
Switch
To test run your machine:
1. Make sure the main power switch (see
Figure 25) is turned OFF.