Lincoln Electric SVM178-B Welding System User Manual


 
0 volts
20V
0.1ms
This is the typical DC output voltage
generated from a properly operating
machine in the Constant Current (CC)
mode.
Note that each vertical division repre-
sents 20 volts and that each horizon-
tal division represents 0.1 millisec-
onds in time.
The machine was loaded with a
resistance grid bank to 500 amps at
40 volts.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep..0.1 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL WELD VOLTAGE WAVEFORM (STICK CC)
MACHINE LOADED TO 500 AMPS AT 40 VOLTS
TROUBLESHOOTING AND REPAIR
F-49 F-49
VANTAGE® 500