INSTALLATION
A2.2 A2.2
VANTAGE® 500
TECHNICAL SPECIFICATIONS - VANTAGE 500 DEUTZ (K2405-1)
INPUT - DIESEL ENGINE
Make /Model Description Speed (RPM) Displacement Starting Capacities
System
DEUTZ 4 cylinder High Idle 1890 190 cu. in 12VDC battery Fuel
F4L2011 48HP (36 kw) Low Idle 1425 (3.1L) & Starter 25 US gal.
Diesel Engine @ 1800 RPM Full Load 1800 (94.6L)
Bore x Stroke Oil:
2.5 US gal.
3.70” x 4.41” (9.5L)
(94mm x 112mm)
RATED OUTPUT @ 104°F(40°C) - WELDER
Duty Cycle Welding Output Volts at Rated Amps
100% 500 Amps (DC multi-purpose) 40 Volts
60% 550 Amps (DC multi-purpose) 36 volts
50% 575 Amps (DC multi-purpose) 35 volts
PHYSICAL DIMENSIONS
Height
(2)
Width Depth Weight
42.0 in 31.5 in. 63.1 in. 1532lbs.
(1066.8 mm) (800.1mm) (1603mm) (695kg)
(Approx)
1. Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.
2. Top of Enclosure. Add 8.9” (226mm) for exhaust.
OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR
Welding Range
30 - 575 Amps CC/CV
20 - 250 Amps TIG
Open Circuit Voltage
60 Max OCV @ 1900 RPM
Auxiliary Power
(1)
120/240 VAC
12,000 WATTS, 60 Hz., Single Phase
20,000 WATTS, 60 Hz., Three Phase