Lincoln Electric V250-S Welder User Manual


 
F-55
TROUBLESHOOTING & REPAIR
F-55
7. Carefully remove the input rectifier
bridge.
8. When installing a new input rectifier
apply a thin coating of Dow Corning
340 Heat Sink Compound (Lincoln
E1868) to the mating surfaces.
Torque the mounting cap screws
and nuts to 44 IN-LBS.
9. Reconnect the eight leads to the cor-
rect terminals and torque the phillips
head screws to 31 IN-LBS.
INPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT (continued)
INVERTEC V250-S