Important Two-C
omponent Material Information
Foam Resins wi
th 245 fa Blowing
Agents
Some foam blow
ing agents will froth at temperatures
above 90°F (3
3°C) when not under pressure,
especially i
f agitated. To reduce frothing, minimize
preheating i
n a circulation system.
Changing Mate
rials
Changing the material types used in your equipment
requires special attention to avoid equipment damage
and downtime.
• When changin
g materials, flush the equipment
multiple tim
es to ensure it is thoroughly clean.
• Always clean
the fluid inlet strainers after flushing.
•Checkwithy
our material manufacturer for chemical
compatibil
ity.
• When changi
ng between epoxies and urethanes
or polyure
as, disassemble and clean all fluid
component
s and change hoses. Epoxies often
have amine
s on the B (hardener) side. Polyureas
often have
amines on the B (resin) side.
8 3A1705J