Graco 3A1705J Paint Sprayer User Manual


 
Troubleshootin
g
Error
Code
Error
Position
Type Name
Cause Solution
Bad Connectio
n between
MCM (Port 2) an
dload
center board.
Check connect
ion and
cables.
WMCE MCM
ALARM
Load Center Fa
ult
Bad load cent
er.
Replace load center. See
System Repair manual.
WSCX
ADM
ADVISORY Invalid CAN
Configuration
Duplicate node on CAN
network.
Verify LPTCM are set to A
and B.
A valid con
figuration file
can't be fo
und for the
USB.
Insert a system token into
theADMandcyclethe
power. Wait until the lights
on USB port stop flashing
before removing the token.
WSUX USB ADVISORY USB Invali
d
Configurat
ion
Bad ADM.
Replace A
DM. See System
Repair ma
nual.
WXUD ADM
ADVISORY USB Download
Error
Log download failed. Backup and reformat the
USB drive. Retry download.
WXUU ADM
ADVISORY USB Upload Error Custom language file
failedtoupload
Perform normal USB
download and use the new
disptext.txt file to upload the
custom language.
WX00
MCM
ALARM External Input The alarm external input
hasbeendrivenlow.
An active alarm is being
generated by the external
trigger. If the external alarm
is not configured check for a
short in the wiring going to
MCM port 7, pins 1 and 3.
88 3A1705J