Graco 3A1705J Paint Sprayer User Manual


 
Proportioner Mo
dels
Proportioner Models
E-30i Series
Includes:Part Available
Auxiliary
Current at
240 V, 60
Hz*
Booster
Heat
(4000
Watts)
Air
Compressor
(5000 Watts)
Voltage
(phase)
Total
System
Load
(Watts)
Max Flow
Rate lb/min
(kg/min)
Approxi-
mate Out-
put per Cy-
cle (A+B)
gal. (liter)
Maximum
Fluid
Working
Pressure
psi (MPa,
bar)
259079
50 Amps 240 V (1)
7,700
30 (13.5)
0.0272
(0.1034)
2000 (13.8,
138)
259080
32 Amps
240 V (1)
11,700
30 (13.5)
0.0272
(0.1034)
2000 (13.8,
138)
259089
30 Amps
240 V (1)
7,700
30 (13.5)
0.0272
(0.1034)
2000 (13.8,
138)
259090
12 Amps

240 V (1)
16,700
30 (13.5)
0.0272
(0.1034)
2000 (13.8,
138)
E-XP2i Series
Includes:Part Available
Auxiliary
Current at
240 V, 60
Hz*
Booster
Heat
(4000
Watts)
Air
Compressor
(5000 Watts)
Voltage
(phase)
Total
System
Load
(Watts)
Max Flow
Rate gpm
(lpm)
Approxi-
mate Output
per Cycle
(A+B) gal.
(liter)
Maximum
Fluid
Working
Pressure psi
(MPa, bar)
259081
32 Amps
240 V (1)
11,700
2.0 (7.6)
0.0203
(0.0771)
3500 (24.1,
241)
259091
12 Amps

240 V (1)
16,700
2.0 (7.6)
0.0203
(0.0771)
3500 (24.1,
241)
Total system watts used by system, based on maximum heated hose length of 310ft(94.5m)for
each unit.
* Full load amps available for auxiliary equipment when all bare-system components are operating
at maximum capabilities. Available auxiliary current is based on 310 ft (94.5 m) of heated hose.
An additional 3.0 amps of auxiliary current is available for each 50 ft (15.2 m) section of heated
hose that is not used.
Avai
lable auxiliary current will be less when the engine is de-rated for site altitude. Reduce the
Avai
lable Auxiliary Current in the chart by 2.5 Amps per 1000 ft (300 m) elevation increments. If the
avai
lable auxiliary current is less than zero, the system configuration may not support the full load
at th
at altitude.
Includes Complete Air Compressor Kit 24K335.
Refer to Circuit Breaker Configuration Options, page 29.
Se
e Approvals, page 10.
3A1705J 9