Table A.7 External I/O S7 (12 pin – terminal block)
PIN Lead # Function
1 851 +15vdc for Trigger group
2 852 Trigger input
3 853 Dual procedure input
4 854 4 step input (Disabled as of S25564-19)
5 855 +15vdc for cold inch group (Disabled as of S25564-19)
6 856 cold inch forward
7 857 cold inch reverse
8 858 gas purge input
9 859 +15vdc for shutdown group
10 860 shutdown1 input
11 861 shutdown2 input
12 862 input B
Table A.9 Ethernet Connector S9 (8 pin – RJ-45 Style Connector / cat 5 Cable)
PIN Function
1 Transmit +
2 Transmit -
3 Receive +
4 ---
5 ---
6 Receive -
7 ---
8 ---
Table A.8 Master / Slave I/O and System Interface Output Receptacles (22 Pin – MS bayonet style)
Pin Master / Slave Input Master / Slave Output Optional System Interface
(S12) (S13) (ARC1, ARC2, ARC3, ARC4)
A Reserved for future use Reserved for future use ---
B Reserved for future use Reserved for future use ---
C Sync In Reserved for future use Sync Out
D Sync In Reserved for future use Sync Out
E Ready In Ready In ---
F Ready In Ready In ---
G Polarity Out Polarity Out ---
H Polarity Out Polarity Out ---
I Ground --- ---
J Reserved for future use Reserved for future use ---
K Reserved for future use Reserved for future use ---
L +40v (COM) Reserved for future use ---
M +40v ("+") Reserved for future use ---
N Reserved for future use Reserved for future use ---
P Reserved for future use Reserved for future use ---
R Reserved for future use Reserved for future use ---
S Reserved for future use Reserved for future use ---
T Drain (ethernet) Drain (ethernet) ---
U Kill Out Kill Out ---
V Kill Out Kill Out ---
W Work voltage sensing (21) Work voltage sensing (21) ---
X Electrode Voltage Sensing (67) Electrode Voltage Sensing (67) ---