Lincoln Electric SVM125-A Welder User Manual


 
ELECTRIC SHOCK can kill.
• Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY
LEAD before servicing.
• Do not touch electrically live parts.
MOVING PARTS can injure.
• Keep guards in place.
• Keep away from moving parts.
• Only qualified personnel should install,
use or service this equipment.
CONNECTION OF THE LN-7 TO THE
CLASSIC II USING K867 UNIVERSAL
ADAPTER (SEE FIGURE C.1.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-7 to the
“+” terminal of the welder. Connect the work
cable to the “CV–” terminal of the welder.
NOTE: Welding cable must be sized for current
and duty cycle of application.
NOTE: Figure C.1 shows the electrode connected
for positive polarity. To change polarity,
shut the welder off and reverse the elec-
trode and work cables at the Classic II
output terminals.
3. Connect the K867 Universal Adapter to the K291 or
K404 input cable and the 14 pin amphenol of the
Classic II as indicated in Figure C.1. Make the
proper connections for local or remote control
according to Figure C.1.
4. Connect the K291 or K404 input cable to the LN-7.
5. Place the IDLER switch in the “HIGH” position.
Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
6. Adjust wire feed speed and voltage at the LN-7.
NOTE: For remote control, a K775 remote control is
required. See Figure C.1.
When the welder is in local control, the electrode is
always “HOT.”
ACCESSORIES
C-4 C-4
CLASSIC II
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS
WARNING
CAUTION
CAUTION
FIGURE C.1
CLASSIC II/LN-7 WITH K867 ADAPTER CONNECTION DIAGRAM
Classic II Output
Terminals are on
Opposite Side
Splice Leads
and Insulate
Insulate Each
Unused Lead
Individually
TO
WORK
14 PIN
AMPHENOL
LN-7
CONTROL
BOX
SPARE
82
81
42
41
31 31
32 32
22
44
21
75
76
77
75
76
77
21
GND GND
GREEN
K291 OR K404
INPUT CABLE
K775 OPTIONAL
REMOTE CONTROL
K867 UNIVERSAL
ADAPTER PLUG
ELECTRODE CABLE
TO LN-7
CV-
+