Lincoln Electric SVM125-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INSTALLATION
A-2 A-2
CLASSIC II
TECHNICAL SPECIFICATIONS - CLASSIC II
INPUT - DIESEL ENGINE
Manufacturer Description Speed Displacement Ignition Capacities
Deutz 3 cyl., 1725 RPM 125 cu. in. Electric Fuel: 15 gal.
F3L-1011F Air-cooled Full load (2049 cc) (57 liters)
diesel Oil: 6.3 qt.
28 HP @ 1800 RPM (6.0 liters)
1700 RPM High idle
1350 RPM
Low idle
RATED OUTPUT - WELDER
Duty Cycle Amps Volts at Rated Amperes
100% Duty Cycle 200 DC Constant Current 28V
60% Duty Cycle 250 DC Constant Current 40V
40% Duty Cycle 300 DC Constant Current 32V
OUTPUT - WELDER AND GENERATOR
Welding Ranges Max. Open Circuit Voltage Auxiliary Power
(1)
40-325 Amps DC 98.5 3.0 kVA of 115/230 V, 60Hz Power
26 Amps @ 115 V
13 Amps @ 230 V
PHYSICAL DIMENSIONS
Height Width Depth Weight
49.94 in. 24 in. 60 in. 1340 lb.
1040 mm 610 mm 1524 mm 608 kg
1
CSA machines can draw 15 amps from either half of the receptacle. Non-CSA machines can draw 20 amps from either half of the
receptacle. Total combined load of all receptacles cannot exceed 3.0 kVA.