Lincoln Electric SVM125-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-48 F-48
CLASSIC II
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
Mode No Load RPM Load RPM
Low Idle 1350-1400 NA
High Idle 1780-1810 1650-1740
WELDER DC OUTPUT
Current Control Current Selector Open Circuit Load Volts Load Amps
Rheostat Switch Voltage
Maximum Maximum 91-98.5 38-45 300
AC AUXILIARY POWER RECEPTACLE OUTPUT
230 Volt Receptacle 115 Volt Receptacle
Open Circuit Load Volts Load Amps Open Circuit Load Volts Load Amps
Voltage Voltage
240-254 210-225 13.8 118-128 103-112 26.0
FIELD AMPS AND VOLTS
(Current Rheostat at Maximum)
Exciter DC Volts Shunt Field Amps Alt. Rotor Amps RPM
123 - 133 1.90 - 2.30 2.2 - 2.6 1780 - 1810