Lincoln Electric SVM125-A Welder User Manual


 
MAINTENANCE
D-5 D-5
CLASSIC II
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TABLE D.1
DEUTZ ENGINE MAINTENANCE SCHEDULE
FREQUENCY MAINTENANCE REQUIRED
Daily or Before
Starting Engine
• Fill fuel tank.
Check oil level.
• Check air cleaner for dirty, loose, or damaged parts.
• Check air intake and cooling areas, clean as necessary.
First 50 Hours • Change engine oil.
• Change oil filter.
• Change fuel filter.
• Check fan belt.
Every 50 Hours • Check fuel lines and clamps.
Every 100 Hours • Check battery electrolyte level and connections.
Refer to your Deutz engine Owner's Manual for periodic maintenance at 100 hours and beyond.