Lincoln Electric SVM138-A Welder User Manual


 
Test Meter PC Board Wire Feed Speed Accuracy.
(Metric Models Only)
1. Use a test meter with at least 3-1/2 digits and
± 0.5% accuracy.
2. Connect the + probe to lead called for in the table
below and the - probe to lead #510C.
NOTE: The coating will have to be removed from the
test points.
3. With the meter in SET M/MIN, adjust the speed
control until the LN-9 GMA meter matches the set-
tings in the table below. If the test meter does not
match the readings, the meter PC board may be
faulty. Replace the meter PC board.
TROUBLESHOOTING & REPAIR
F-45 F-45
LN-9 GMA Wire Feeder
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
METER CIRCUIT ACCURACY TEST (continued)
METRIC MODEL METRIC RANGE SET M/MIN READING TEST VOLTMETER
READING
LN-9 GMA or LN-9F GMA LO 8.28 LEAD #560
2.00 ± .05VDC
HI 24.8 LEAD #561
6.00 ± .07VDC