Lincoln Electric SVM138-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-55 F-55
LN-9 GMA Wire Feeder
FIGURE F.13 – METER PANEL ASSEMBLY SCREWS
MOUNTING SCREWS
METER
DIGITAL METER AND METER PC BOARD REMOVAL AND
REPLACEMENT (continued)
METER PC BOARD REMOVAL
PROCEDURE
1. Remove input power to the LN-9 GMA Wire
Feeder.
2. Locate and remove the two screws on the top
left and right side of the meter panel assem-
bly. See Figure F.13.
FIGURE F.14 – METER REMOVAL (WITH SHORT LEADS)
3. Lift the right side cover assembly. 4. Carefully remove the meter enclosure panel.
Note the limited lead length. See Figure F.14.