Lincoln Electric SVM138-A Welder User Manual


 
HALL EFFECT MODULE TEST AND ALIGNMENT
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshoot-
ing assistance before you proceed. Call 216-383-2531 or 1-800-833-9353 (WELD).
DESCRIPTION
This test will help determine if the Hall Effect Module is correctly aligned and functioning prop-
erly.
MATERIALS NEEDED
9/16” Wrench
Analog volt/ohmmeter (multimeter)
Phillips head screwdriver
TROUBLESHOOTING & REPAIR
F-34 F-34
LN-9 GMA Wire Feeder
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
WARNING
The Hall Effect Module Test takes approximately
10 minutes to perform.
The Hall Effect Alignment Procedure takes approximately
10 minutes to perform.