Lincoln Electric SVM138-A Welder User Manual


 
The following Figures D.2 and D.3 should serve as a
guide to determine if a particular gun or switch can be
connected to the LN-9 GMA and LN-9F GMA.
“A” Diameter Hole
to be Concentric to
Wire Size .749/.747 (19.0/18.9)
in. (mm) Diameter Within .008 (.20) F.I.M.
0.68-5/64 (1.7-2.0) .125 [1/8” (3.2 mm) Drill]
1/16-0.062 (1.6) .078 [5/64” (2.0 mm) Drill]
.045 & .052 (1.1 & 1.3) .062 [1/16” (1.6 mm) Drill]
.023-.035 (0.6-0.9) .055 [(1.4 mm) #54 Drill]
All dimensions in inches and (millimeters).
1/2 Amp AC 24 Volts — Inductive
1/2 Amp DC 24 Volts — Inductive
MAINTENANCE
D-4 D-4
LN-9 GMA Wire Feeder
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
FIGURE D.2 – LN-9 GMA CONNECTORS
GUN CABLE CONNECTOR REQUIRE-
MENTS TO PERMIT PROPER CONNEC-
TION TO LINCOLN LN-9 GMA AND LN-9F
GMA WIRE FEEDER
LN-9 CONNECTOR FOR 1/16-5/64” (1.6-2.0 MM) WIRE)
LN-9 CABLE CONNECTOR FOR .023-.052” (0.6-1.3 mm)
WIRE (FOR ALL OTHER DIMENSIONS, SEE DIAGRAM
ABOVE).
NOTE: Connector part with .7459/.747 (19.0/18.9)
diameter should be made from brass if it is to be part
of the welding current carrying circuit.
FIGURE D.2 – SWITCH REQUIREMENTS