Lincoln Electric SVM138-A Welder User Manual


 
F-66 F-66
LN-9 GMA Wire Feeder
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
DRIVE MOTOR REMOVAL AND REPLACEMENT (continued)
11. Remove the three screws and lock washers
that hold the glastic mounting to the LN-9
GMA floor assembly. It may be necessary to
remove the copper reed switch energizer to
access one of the mounting screws. See
Figure F.23.
NOTE: Four- roll drive units have nuts and wash-
ers also. Screw heads are located under the
Mylar insulator.
FIGURE F.23 – GLASTIC MOUNTING SCREWS
NUTS AND
WASHERS
(4-ROLL
FEEDERS)