Figure A.8 is a connection diagram for connecting the
LN-9 GMA to V300 power sources. The connection is
made with a K596 cable assembly, which has an
amphenol connection rather than a terminal strip con-
nection at the power source.
Depending on the power source and process you are
using, the jumpers on the LN-9 GMA voltage board
may have to be changed. As shipped, the LN-9 GMA is
connected for use with the DC-250 DC-400, CV-400,
CV-500-I and DC-600. For other power sources, refer
to the appropriate connection diagram.
NOTE: If you are using the Pulse Power 500, DC650
Pro, or V300 power source, the K442-1 Pulse Power
Filter Kit must be installed in the LN-9 GMA. See the
instructions included with the kit. If you are using the
Invertec V300, the K608-1 Adapter must also be
installed according to the connection diagram and
instructions provided in the Invertec Manual.