Lincoln Electric SVM152-A Welding System User Manual


 
V350-PRO
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-72 F-72
FIGURE F.30 – STATUS BOARD LOCATION
WARNING
REMOTE
POWER
OFF
ON
A
AMPS
A
V
VOLTS
WELD TERMINALS
SELECT
OUTPUT
LINCOLN
ELECTRIC
INVERTEC V350-PRO
L11130-1
CS 71D1
Display Board
L11 10 7-2
STATU
S I N
PU
T
Status Board
L11110-1
MODE SELECT
Mode Board
STATUS BOARD REMOVAL AND REPLACEMENT (continued)
PROCEDURE
1. Remove input power to the V350-PRO.
2. Using a 5/16” nut driver remove the case
wraparound cover.
3. Perform the Input Filter Capacitor
Discharge Procedure detailed earlier in this
section.
4. Locate the status board behind the front
panel of the machine. See Figure F.30.