Lincoln Electric SVM152-A Welding System User Manual


 
PROCEDURE
1. Remove input power to the V350-PRO.
2. Using a 5/16” nut driver remove the case wrap-
around cover.
3. Perform the Input Filter Capacitor Discharge
Procedure detailed earlier in this section.
4. Remove the caps on the two wire feeder recepta-
cles.
5. Using a phillips head screwdriver remove the two
mounting screws from each wire feeder recepta-
cle. See Figure F.40.
6. Using a 5/16” nut driver remove the four screws
from the top and bottom of the back of the
machine. See Figure F.40.
TROUBLESHOOTING & REPAIR
CURRENT TRANSDUCER REMOVAL AND REPLACEMENT (continued)
F-90 F-90
V350-PRO
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
OFF OFF OFF
OFF
Wire Feeder Receptacle
Mounting Screws
Plastic
Nut
5/16" Mounting Screws
REAR
FIGURE F.40 – CASE BACK SCREW LOCATIONS