Lincoln Electric SVM152-A Welding System User Manual


 
V350-PRO
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
A-2
INSTALLATION
A-2
TECHNICAL SPECIFICATIONS -
INVERTEC V350-PRO
INPUT AC VOLTAGE & DC OUTPUT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Product Ordering Input AC Rated DC Output Output Weight
Name Information Voltage Amps/Volts/Duty Cycle Range with Cord HxWxD
(continuous)
K1728-1 200-230 / 200-230/ 350A / 34V / 60%
Factory 380-415/ Factory
460-480/ 275A / 31V / 100% 82.5lbs 14.7”x12.5”x
Invertec 575 (37.4 kg) 27.8”*
V350- K1728-2 3 Phase AMPS (373x318x
PRO Construction 60/50 Hz 5-425 Construction 706*)mm
60/50 Hz
81.5lbs
208-230/ 350A / 34V / 60% (36.9 kg) * Includes
K1728-3 415/ handles
“CE” 460-480/ 275A / 31V /100%
575
1 Phase
* Overall Length Including Handle, 27.8” (706mm) without handle.
Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE CURRENT LENGTH UP 61m (200 FT) 61-76m (200-250 FT)
100% 275 1/0 1/0
60% 350 1/0 2/0
V350-PRO INPUT CURRENT
1. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz Output Recommended
Voltage Phases 275Amps@ 350Amps@ Line Cord Size Fuse Size Notes
31Volts(100%) 34Volts(60%)
208 1 70 94 2 125A Note 1
230 1 62 85 4 125A Note 1
415 1 38 54 6 80A Note 1
460 1 34 42 8 70A
575 1 27 37 8 50A
200 3 37 50 8 80A Note 1
208 3 36 50 6 80A Note 1
230 3 31 42 8 70A
380 3 21 28 8 50A
400 3 20 27 8 50A
415 3 19 26 8 50A
460 3 17 23 8 50A
575 3 14 18 8 35A