PROCEDURE
1. Remove input power to the V350-PRO.
2. Using a 5/16” nut driver remove the case
wraparound cover.
3. Perform the Input Filter Capacitor Discharge
Procedure detailed earlier in this section.
4. Locate the input rectifier. See figure F.36.
5. Carefully remove the silicon sealant insulating the
six input rectifier terminals.
6. Remove the six screws from the terminals using a
flathead screwdriver. Carefully note the position of
all leads and their positions upon removal. See
Figure F.37.
7. Using a 3/16”in. allen wrench remove the two
mounting screws and washers from the input
bridge. See Figure F.37.
8. Remove the input bridge.