Mitsubishi Electronics 882.00207.00 Engraver User Manual


 
882.00207.00 Chapter 4: Operation 57 of 102
PLC Battery Low
PLC battery is low and may cause the blender to lose both the program and the blender
configuration. Notify Maintenance immediately.
Typical “PLC Battery Low” Alarm Screen
Blender Powered On/Off
These are only logged in the Alarm Log and does not cause a pop-up message or audible alarm.
Each time the blender is powered on or off, the time and day is logged to the Alarm Log.
Inventory Cleared
This is only logged in the Alarm Log and does not cause a pop-up message or audible alarm. Each
time the inventory is cleared, the time and date are logged to the Alarm Log. An alarm will sound
and a screen will pop up when Auto. Inventory Shutdown has been reached.
E-Stop Screen
The blender is equipped with an E-stop switch that removes the power from all mechanical outputs.
The E-Stop Screen appears along with an audible alarm whenever the E-Stop is activated. The
operator cannot access any screens until E-Stop is deactivated. The Panel View will then put the
screen back to the display that the operator was on prior to pressing the E-Stop button.
Typical “E-Stop Activated” Alarm Screen
PLC BATTERY LOW