Fujitsu MHC2040AT Drill User Manual


 
5.6 Timing
C141-E050-02EN 5-97
5.6.4.2 Ultra DMA data burst timing requirements
Table 5.16 Ultra DMA data burst timing requirements (1 of 2)
NAME
MODE 0
(in ns)
MODE 1
(in ns)
MODE 2
(in ns)
COMMENT
MIN MAX MIN MAX MIN MAX
t
CYC
114 75 55
Cycle time (from STROBE edge to
STROBE edge)
t2
CYC
235 156 117
Two cycle time (from rising edge to next
rising edge or from falling edge to next
falling edge of STROBE)
t
DS
15 10 7
Data setup time (at recipient)
t
DH
3 3 3
Data hold time (at recipient)
t
DVS
70 48 34
Data valid setup time at sender (from data
bus being valid until STROBE edge)
t
DVH
6 6 6
Data valid hold time at sender (from
STROBE edge until data may become
invalid)
t
FS
0 230 0 200 0 170
First STROBE time (for device to first
negate DSTROBE from STOP during a
data in burst)
t
LI
0 150 0 150 0 150
Limited interlock time (see Note 1)
t
MLI
20 20 20
Interlock time with minimum (see Note 1)
t
UI
0 0 0
Unlimited interlock time (see Note 1)
t
AZ
10 10 10
Maximum time allowed for output drivers
to release (from being asserted or negated)
t
ZAH
20 20 20
t
ZAD
0 0 0
t
ENV
20 70 20 70 20 70
Envelope time (from DMACK- to STOP
and HDMARDY- during data in burst
initiation and from DMACK to STOP
during data out burst initiation)
t
SR
50 30 20
STROBE-to-DMARDY-time (if DMARDY-
is negated before this long after STROBE
edge, the recipient shall receive no more than
one additional data word)
Minimum delay time required for
output drivers to assert or negate (from
released state)