Fujitsu MHC2040AT Drill User Manual


 
5.3 Host Commands
C141-E050-02EN 5-27
A host system can select the following transfer mode using the SET FEATURES
command.
1) Single word DMA transfer mode 0 to 2
2) Multiword DMA transfer mode 0 to 2
3) Ultra DMA transfer mode 0 to 2
At command issuance (I/O registers setting contents)
1F7
H
(CM)
1 1 0 0 1 0 1 R
1F6
H
(DH)
×
L
×
DV
Start head No. /LBA [MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
Start cylinder No. [MSB] / LBA
Start cylinder No. [LSB] / LBA
Start sector No. / LBA [LSB]
Transfer sector count
xx
R = 0 with Retry
R = 1
without Retry
At command completion (I/O registers contents to be read)
1F7
H
(ST)
Status information
1F6
H
(DH)
×
L
×
DV
End head No. /LBA [MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
End cylinder No. [MSB] / LBA
End cylinder No. [LSB] / LBA
End sector No. / LBA [LSB]
00 (*1)
Error information
*1 If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.
(8) WRITE VERIFY (X’3C’)
This command operates similarly to the WRITE SECTOR(S) command except
that the device verifies each sector immediately after being written. The verify
operation is a read and check for data errors without data transfer. Any error that
is detected during the verify operation is posted.