HP (Hewlett-Packard) J6000 work stations Work Light User Manual


 
48 Chapter2
Troubleshooting
Identifying LCD-Indicated Conditions
TST 2n80 SYS BD CPU
n
dcache tag CPU n is starting its data cache tag
self-test.
TST 2n90 SYS BD CPU
n
dcache ECC CPU n is starting its data cache ECC
self-test.
FLT 2BAD SYS BD assertion fail A firmware assertion failed.
TST 3n00 SYS BD ROM checksum tst Monarch CPU n is testing the boot ROM
integrity.
FLT 3n00 SYS BD ROM checksum BAD The boot ROM failed checksum.
INI 3n00 SYS BD ROM checksum ok The boot ROM passed checksum.
TST 3n01 SYS BD PDH control test Monarch CPU n is testing PDH control
register.
INI 3n01 SYS BD PDH control init Monarch CPU n is initializing the PDH
control register.
FLT 3n01 SYS BD PDH control err Monarch CPU n detected an error in the
PDH control register.
TST 3n02 SYS BD scratch RAM test Monarch CPU n is testing scratch RAM.
INI 3n02 SYS BD scratch RAM ok The scratch RAM test failed.
FLT 3n02 SYS BD scratch RAM bad The scratch RAM test passed.
WRN 3n03 SYS BD stbl st read err CPU n detected a non-fatal error reading
the stable store.
FLT 3n03 SYS BD stbl st read err CPU n detected a non-fatal error reading
the stable store.
INI 3nC4 SYS BD clearing EEPROM Monarch CPU n is clearing the EEPROM.
INI 3nD4 SYS BD deflting EEPROM2 Monarch CPU n is initializing the
EEPROM to system defaults.
WRN 3n04 SYS BD EEPROM write err CPU n detected a non-fatal error writing
the EEPROM.
FLT 3n04 SYS BD EEPROM write err CPU n detected a fatal error writing the
EEPROM.
FLT 3n05 SYS BD EEPROM wrt limit CPU n detected a fatal error writing the
EEPROM.
WRN 3n06 SYS BD EEPROM read err CPU n detected a non-fatal error reading
the EEPROM.
FLT 3n06 SYS BD EEPROM read err CPU n detected a fatal error reading the
EEPROM.
Table 2-1. Chassis Codes for J6000 Workstations
Ostat Code FRU Message Description