HP (Hewlett-Packard) J6000 work stations Work Light User Manual


 
52 Chapter2
Troubleshooting
Identifying LCD-Indicated Conditions
TST 7020 SYS BD search for IMM Try to find a single memory bank to use
for the initial memory module.
TST 703s DIMM DIMM
s
IMM vrfy DIMM s was the initial memory module
last boot. Verify it still works.
FLT 704s DIMM DIMM
s
IMM fail DIMM s failed the initial memory module
test.
TST 705s DIMM DIMM
s IMM test
Test DIMM in slot s as the initial memory
module.
INI 706s DIMM DIMM
s
is IMM DIMM s chosen as initial memory module.
INI 70F0 DIMM DIMM scan done Memory DIMM scan complete.
TST 7100 SYS BD mem register tst Start testing registers in memory
controller.
WRN 7101 SYS BD skip mem reg tst Bypass the memory controller register
test.
FLT 7102 SYS BD mem addr reg tst Firmware detected an error in the
memory controller address registers.
FLT 7103 SYS BD mem mbat reg tst Firmware detected an error in the
memory controller bank registers.
FLT 7104 SYS BD mem reg tst fail Firmware detected an error in the
memory controller memory registers.
FLT 7105 SYS BD mem err reg test Firmware detected an error in the
memory controller error registers.
FLT 7106 SYS BD mem err clr fail Firmware was unable to clear the error
registers after testing.
INI 7200 DIMM strt DIMM detect Start the Serial Presence Detection (SPD)
to search for memory DIMMs.
INI 7201 DIMM DIMM detect
x
% SPD is x% finished.
WRN 7202 SYS BD skip DIMM detect Bypass Serial Presence Detection.
FLT 7203 DIMM unsupp DIMM type SPD found an unsupported DIMM type.
FLT 7204 DIMM SPD fatal error SPD detected an unexpected, fatal error.
INI 7205 DIMM add HP DIMM type New HP manufactured DIMM type added
to tables.
INI 7206 DIMM non-HP DIMM type New non-HP DIMM type added to tables
(use at own risk).
Table 2-1. Chassis Codes for J6000 Workstations
Ostat Code FRU Message Description