Using the System Board LEDs for Troubleshooting
VRM0 OFF If the following solutions do not bring this LED back
on, replace VRM0 board.
Swap VRM cards to determine if VRM0 is bad
Determine that the power cable to the system is
plugged in
Check that the power button has been pressed on
Re-seat the VRM0 board in its connector
Check that the VRM0 connector cable is properly
plugged in
FETCH OFF If the following solutions do not bring this LED back
on, replace the system board.
Look at the system’s LCD to determine if the
firmware update process has been interrupted
Determine that the power cable to the system is
plugged in
Check that the power button has been pressed on
Determine that all external peripheral devices are
turned on and that their cables are properly
connected
Check that all internal devices are powered on and
that their cables are properly connected
Table 2-4. Solutions for the Non-Default LED States
LED Name
1
Non-Default
State
Solution