Troubleshooting
Identifying LCD-Indicated Conditions
INI 3n07 SYS BD CPU
n
invoke LDB CPU n is starting the low-level debugger.
FLT 3n09 SYS BD bad sys mde byte CPU n detected an unsupported system
mode.
WRN 3n1A SYS BD hversion mismtch Stable store hardware version doesn’t
match system.
TST 3n1B SYS BD chck model strng Check model string with version in stable
store.
WRN 3n1B SYS BD model str msmtch Model string doesn’t match that in stable
store.
FLT 3n1B SYS BD fatal model str Error reading model string from stable
store.
TST 3n1C SYS BD test software ID Check LANIC address.
WRN 3n1C SYS BD update sw ID Update LANIC address.
FLT 3n1C SYS BD update sw ID err Error updating LANIC address.
INI 3n2s SYS BD Invoke LDB:
s
CPU n is awaiting the low-level debugger
for s more seconds.
TST 3nBC IO BD test sys clocks CPU n is verifying processor clocks with
the real-time clock.
INI 3nBC SYS BD init sys clocks CPU n has initialized the processor clocks.
FLT 3nBC IO BD RTC tick timeout The real-time clock is ticking too slowly or
not at all.
TST 3nCD SYS BD check defaults CPU n is initializing stable store values to
system defaults.
INI 3nCD SYS BD init defaults CPU n finished initializing stable store
values.
FLT 3nCD SYS BD init EEPROM err CPU n detected an error writing to stable
store.
FLT 3nEC SYS BD bad sys config CPU n detected an illegal CPU board
configuration.
FLT 3nF4 SYS BD EEPROM boot limt CPU n detected a fatal error writing the
EEPROM.
FLT 3nFC SYS BD bad sys bd id CPU n cannot identify CPU board.
TST 4n00 SYS BD CPU
n
start lst CPU n is starting its late (with memory)
self-tests.
Table 2-1. Chassis Codes for J6000 Workstations
Ostat Code FRU Message Description