HP (Hewlett-Packard) J6000 work stations Work Light User Manual


 
Chapter 2 53
Troubleshooting
Identifying LCD-Indicated Conditions
FLT 7207 DIMM DIMM table full The DIMM table is full--cannot add new
type.
FLT 7208 DIMM no DIMMs found SPD didn’t find any memory DIMMs.
INI 721s DIMM is DIMM
s
inst? SPD is checking memory slot s.
INI 722s DIMM ???? DIMM in
s
SPD found a DIMM in slot s, but can’t
determine its size. DIMM will not be used.
INI 723s DIMM 128M DIMM in
s
SPD found a 128MB DIMM in slot s.
INI 724s DIMM 256M DIMM in
s
SPD found a 256MB DIMM in slot s.
INI 725s DIMM 512M DIMM in
s
SPD found a 512MB DIMM in slot s.
FLT 72As DIMM DIMM
s
checksum DIMM in slot s failed SPD checksum and
will not be used.
FLT 72Cs DIMM DIMM
s
mismatch DIMM in slot s didn’t match the other in
pair. (J7xxx only--DIMMs must be in
matched pairs.)
FLT 72Ds DIMM DIMM
s
load err Memory DIMMs are not in the proper
order. As a result, the system cannot
access DIMM s and has deallocated it.
INI 7300 SYS BD mem config start Starting main memory configuration.
TST 7301 SYS BD check mem config Checking for memory configuration
change since last boot.
WRN 7302 SYS BD mem confg changd Memory physical configuration changed
since last boot.
INI 7303 SYS BD use confg change Memory physical configuration didn’t use
saved configuration change. Use stored
configuration data.
INI 7304 SYS BD build mem intrlv Building memory configuration with all
DIMMs interleaved.
INI 7305 SYS BD save mem config Saving memory configuration information
in non-volatile memory.
WRN 7306 SYS BD use alt mem conf Memory will be configured from fixed
values, instead of detected DIMMs.
INI 7307 SYS BD interleve memory Generating the memory interleave.
FLT 7308 SYS BD PDT is disabled Firmware detected bad memory pages,
but the Page Deallocation Table is
disabled.
Table 2-1. Chassis Codes for J6000 Workstations
Ostat Code FRU Message Description