HP (Hewlett-Packard) J6000 work stations Work Light User Manual


 
Chapter 2 51
Troubleshooting
Identifying LCD-Indicated Conditions
TST 4n60 SYS BD CPU
n
dcache miss CPU n is starting its data cache miss
self-test.
FLT 5n00 SYS BD unknown bus err CPU n detected an unknown error on the
system bus (Runway).
FLT 5n02 SYS BD path err assertd CPU n detected a path error on the
system bus (Runway).
FLT 5n04 SYS BD data parity err CPU n detected a data, address, or control
parity error on the system bus (Runway).
FLT 5n07 SYS BD Runway dir error CPU n detected a directed error on the
system bus (Runway).
FLT 5n08 SYS BD Runway broad err CPU n detected a broadcast error on the
system bus (Runway).
FLT 5n0A SYS BD illegal response CPU n received data that did not match
any outstanding data request.
FLT 5n0B SYS BD bus timeout CPU n timed out before receiving
requested data. The responder is logged in
the system responder address.
FLT 5n0C SYS BD CPU sync failure CPU n’s synchronizer detected a rule
violation on the system bus (Runway).
INI 7000 DIMM start DIMM scan Start looking for installed DIMMs.
INI 7002 SYS BD init mem tables Initialize memory data structures.
FLT 7004 SYS BD mem plt upd fail Error updating memory platform data.
FLT 7005 DIMM insufficient mem Insufficient memory detected to continue.
TST 7010 DIMM check DIMM order Start memory DIMM order check.
WRN 7011 DIMM skip DIMM ord ck Bypass memory DIMM order check.
FLT 7012 DIMM DIMM order error Memory DIMMs are not in the proper
order.
FLT 7013 DIMM DIMM order error Memory DIMMs are not in the proper
order. As a result, the system cannot
access one or more DIMMs and has
deallocated all inaccessible DIMMs.
TST 7016 DIMM DIMM pair check Start memory DIMM pair check (DIMMs
in a pair (e.g. 0a/0b) must match in
J7xxx).
WRN 7017 DIMM skip mem pair ck Bypass memory DIMM set check.
FLT 701F DIMM no memory found Memory scan couldn’t find any DIMMs.
Table 2-1. Chassis Codes for J6000 Workstations
Ostat Code FRU Message Description