Identifying LCD-Indicated Conditions
FLT CBFF SYS BD multiple HPMCs A High-Priority Machine Check occurred
while processing another HPMC.
INI CC0n SYS BD CPU
n
OS rendezvs Slave CPU n entering the final
rendezvous, waiting for the operating
system to awaken it.
INI CC1n SYS BD CPU
n
early rend Slave CPU n entering the early
rendezvous, waiting for the monarch CPU
to initialize scratch RAM and other
system state.
INI CC2n SYS BD CPU
n
rendezvous Slave CPU n entering rendezvous. Slave
CPUs enter this rendezvous numerous
times during boot.
INI CC3n SYS BD CPU
n
cache rend Slave CPU n entering cached rendezvous,
waiting for the monarch CPU to configure
the system bus.
INI CC4n SYS BD CPU
n
mem rendez Slave CPU n entering memory
rendezvous, waiting for the monarch CPU
to select a boot device.
TST D000 SYS BD micro controller Firmware is initializing communications
with the system controller.
WRN D004 SYS BD micro not resp Firmware detected a communications
error with the system controller.
INI D005 SYS BD set dom1 fan spd Firmware is initializing communications
with the system controller.
INI D006 SYS BD set dom2 fan spd Firmware is initializing communications
with the system controller.
WRN D007 SYS BD bad microctl cmd Firmware detected a communications
error with the system controller.
FLT D01n SYS/IO fan
n
: failure! Firmware detected system fan n stopped.
WRN D02n SYS/IO fan
n
: too slow! Firmware detected system fan n is
running too slowly.
Table 2-1. Chassis Codes for J6000 Workstations
Ostat Code FRU Message Description