Ingersoll-Rand 4581740 Saw User Manual


 
20 04581740_ed2
If the Gang Count is successfully completed, in addition to displaying “Gang Complete” on the screen, the controller
provides a gang complete output signal on the spindle’s I/O connector. There are two ways to reset the Gang Count.
1. Use the dedicated reset palm switch on the Gang Reset Input.
2. While on the Run Main screen, press 0 (zero) and then the Enter key to reset the Gang Count for the spindle.
Auto Increment
Auto Increment allows the Insight to move through a specic sequence of fastening Congurations. For example, if
you have programmed six dierent Congurations numbered 1 – 6, you can instruct the Insight to perform fastening
in the sequence 1-4-6 and 2-3-5. By using this parameter to tell the Insight which Conguration to go to next, the
system continues to step through all programmed Congurations in the Auto Increment chain. The Increment Reset
parameter tells the Insight which Conguration to use when the Conguration Reset Input is activated.
NOTE: The present Conguration must be completed successfully and the spindle trigger released before the next
Conguration in the chain is selected.
3.2.3 Start Mode and Cong Select
The nal two steps in the quick setup procedure are done on the Spindle Setup screen, where you must set the Start
Mode and Cong Select parameters before you begin to operate the Insight controller. For information on setting
these parameters, see Spindle Setup Screen on page 23.
3.3 System Setup
3.3.1 Passwords
When your Insight IC-D is rst booted up, it is unlocked, allowing full read and write access. This means that there is no
password protection in place when the system is rst booted up. The default password is 1111.
To begin using the password:
1. Go the Setup menu’s System Setup screen, and scroll down with the arrow keys until you reach the Password
Logout button at the bottom of the screen.
2. Press the Enter key to logout.
3. Return to the System Setup screen and notice that Password Logout button has become Password Login.
4. Press the Enter key to login.
5. When password request popup appears, enter the default password, 1111.
6. Move to the Change Password screen and press Enter to set a new password for the Insight controller.
7. Enter the current password on the popup screen that appears and press Enter.
8. Enter a new 4-digit password twice in the data enter boxes provided.
9. Hit Enter again to set the new password.
10. Go to the Password Timer parameter on the System Setup screen to change the delay after which password
protection takes eect. The available increments are 30 sec, 1 min, 2 min, 5 min, 15 min, and 1 hr.
NOTE: Except when the Password Timer parameter is set to “O,” a Password login is always required after reboot, even
if the password timer increment period has not passed.
3.3.2 Set Date and Time
The Date and Time parameters found on the System Setup screen include Time Set, Time Mode, Date Set, Time
Zone, and Date Format. The time is shown in 24-hour clock format.
To set Date and Time parameters:
1. Go to the System Setup screen and move to the Time Mode parameter.
2. Choose either Manual or Auto (NTP). NTP = Network Time Protocol
NOTE: If you choose Auto (NTP), the Insight controller has its time setting synchronized through the network time
protocol on an Ethernet network upon boot up, The Time Set parameter is not available if NTP is selected.
3. If you select Manual in the Time Mode parameter, go to the Time Set parameter and enter the correct time for
your location, and skip to step 5.
4. If you entered Auto (NTP) in the Time Mode parameter, go to the Time Zone parameter and select the correct
GMT (Greenwich Mean Time) +/- hours for your location.
5. Move to the Date Format parameter to set the format as either MM/DD/YY or DD/MM/YY.
6. Finally, move to the Date Set parameter and enter the current date in the format you selected.