Ingersoll-Rand 4581740 Saw User Manual


 
04581740_ed2 43
Appendix 2 – Event Codes
The following table lists the Event Codes for the IC-D and IC-M. Below is an explanation of table columns.
Event Code Explanation
Event Code
This is the event code number. On an IC-M controller, the code is displayed on the screen as “E” and then the code
number, for example, E002. For a IC-D controller, text detailing the error is placed in the systems dialog and warnings
box at the bottom of the Run Main screen.
Description/Condition
Description of Error.
Critical Error
If yes, then error condition must be resolved before system can run.
Action Required/Explanation
Action required to resolve error
Display on IC-D, IC- M GUI
Indicates which systems the error is displayed on. Some errors of secondary importance are only shown on the I320D
controller.
Event Code Table
Event
Code
Description/Condition
Critical
Error
Action Required/Explanation
Display
on D, M
GUI
Boot-up Events 001 to 060
002 Language File not found Yes Load language le to controller and re-boot D,M
004
A system le has been lost (previously
existed)
No None D
005 Unable to initialize serial port No
Reboot system, If error still occurs call authorized
Ingersoll Rand service center
D, M
006 Unable to initialize Ethernet port No
Reboot system, If error still occurs call authorized
Ingersoll Rand service center
D, M
016 Restore Can2 switch No Restore the Can2 switches to “00” D,M
027 Invalid Boot Image Yes Call authorized Ingersoll Rand service center D,M
028,
029
Invalid Image Yes
Load, Reload new application. If error still occurs
call authorized Ingersoll Rand service center
D,M
030 Error setting IP address No
Reboot system, If error still occurs call authorized
Ingersoll Rand service center
D,M
Tool Events 061 to 080
061 Tool has been disabled through I/O No None D
063 Tool Stall detected No None D, M
064 Tool Hall Fault Yes Check Tool and Tool cable D, M
065 Tool IGBT Fault Yes Check Tool and Tool cable D, M
066 Tool Over Current No Check tool size correct for application D, M
067 Tool Low Bus Voltage No
Ensure Source line voltage is not dropping under
load. If error still occurs call authorized Ingersoll
Rand service center
D, M
068 Tool Cycle Timeout No None D
071 Tool Memory Write Fail No
Check tool cable. Reboot system, If error still occurs
call authorized Ingersoll Rand service center
D, M
072 Tool Memory Read Fail No
Check tool cable. Reboot system, If error still occurs
call authorized Ingersoll Rand service center
D
073 Tool Memory Page Set Fail No
Check tool cable. Reboot system, If error still occurs
call authorized Ingersoll Rand service center
D
074 Tool Factory Null TR No Call authorized Ingersoll Rand service center D, M