Ingersoll-Rand 4581740 Saw User Manual


 
04581740_ed2 31
Shutdown
Code #
Description
121 Powerhead – MCE step sequence error
122 Powerhead – MCE software fault
123 Powerhead – MCE IGBT fault
124 Powerhead – MCE low bus voltage fault
125 Powerhead – MCE hardware watchdog fault
126 Powerhead – MCE calibration failed due to EEPROM mode
127 Powerhead – MCE calibration failed due to oset
128 Powerhead – MCE calibration failed due to shunt calibration
129 Powerhead – spindle was not known to be stopped at cycle complete
130 Powerhead – timeout on start
131 Powerhead – congurations do not match
132 Powerhead – invalid tool connected
133 Powerhead – no tool connected
134 Powerhead – spindle stopped at a sync point
135 Powerhead – spindle in diagnostics mode
To access and use the Cycle Log:
1. Press the Stats button on the Insight controller.
2. On the Statistics menu, select Cycle Log and press Enter.
3. Scroll through the cycles that have been recorded using the arrow keys.
4. Move the cursor to the C (Clear) button and press Enter to clear all existing cycle data.
NOTE: Although using the C button clears data on up to 1,000 cycles, it does not reset the counter. The counter
continues up to 9,999, unless reset with the ICS Software.
Screen Element Description
Clear Cycle Data This button will clear the cycle log data table for the displayed spindle.
Main Window
This window displays the cycle log summary table. Additional information on the parameters
displayed is described below.
5.1.2 Spindle Statistics
The Spindle Statistics screen displays useful statistics that have been calculated from the data collected. Note that on
the left side of the screen displays the statistical data for all the fastenings performed since the statistics were last reset
(the Population Stats), while the right side the statistics for a subset of the cycle (the Sample Stats) The sample size for
Sample Stats is set to 25 by default, but this parameter may be changed in the Stats Settings screen. Both Population
and Sample statistics may also be reset on that screen.
Figure 27 - Spindle Statistics
Note that you must use the dropdown box to select the Conguration from which you wish to view the spindle
statistics. These statistics are only available for the rst eight Congurations. The ICS Software can be set up to calculate
statistics for further Congurations.
To access and use the Spindle Statistics:
1. Press the Stats button on the Insight controller.