Ingersoll-Rand 4581740 Saw User Manual


 
04581740_ed2 33
The nal selection on the Statistics menu is Powerhead Stats. This screen provides useful data when the IC-D is part of
a powerhead Conguration.These statistics are only available when the controller is a powerhead master (the controller
can2 rotary switches must be set to 01).
Figure 29 - Powerhead Stats
Note that the rst data column displays the statistics for the entire powerhead, while the columns to the right show
statistics for the individual spindles in the powerhead, up to as many as 40. The data for the individual spindles is useful
in determining the problem spindles in a powerhead. For instance, if the % Reject under Spindle 5 was 95%, you
would know that the bulk of your reject problems can be traced to that one spindle.
All the values are cumulative, except the Time value, which represents the cycle time for the last cycle. The Population
Size label next to the Conguration box indicates the number of readings used in the statistics calculations displayed
on this screen.
To access and use the Powerhead Statistics:
1. Press the Stats button on the Insight controller.
2. On the Statistics menu, select Powerhead Stats and press Enter.
3. Select the dropdown Conguration box and press the Expand button to view a list of the available Congurations.
4. Select the Conguration for which you wish to view powerhead statistics and press Enter.
5. Use the arrow keys to scroll to the right to view statistics for each spindle included in the powerhead setup.
Screen Element Description
Select Cong
Use this dropbox to select the tightening Conguration whose statistics settings you wish to
change. The options include Conguration 1 through 8 only.