Ingersoll-Rand 4581740 Saw User Manual


 
44 04581740_ed2
Event
Code
Description/Condition
Critical
Error
Action Required/Explanation
Display
on D, M
GUI
USB Events 081 to 100
081
Not enough space to save controller
data to USB key
No Remove excess les for USB key D, M
082
Time out while saving data to the USB
Disk
No
Check that USB key is approved to function with
controller
D, M
083
Time out while loading data to the USB
Disk
No
Check that USB key is approved to function with
controller
D, M
084
Data les on USB key are of an
incompatible version
No
Check Data les on key are of correct version for
the controller
D, M
Communication Events 101 to 120
101
CAN Bus communications between
controllers (Powerhead) has been lost
Yes
Check powerhead synchronization (CAN2) cables
between controllers
D, M
103
CAN Bus communications have been
lost between RISC and MCE
Yes
Reboot system, If error still occurs call authorized
Ingersoll Rand service center
D, M
105 Ethernet DHCP Failed No Check Ethernet connection and DHCP server D, M
110
An invalid Can2 address has been read
from Persistent Storage
No Check value of Can2 (Powerhead) address switches D, M
111 Can 2 Address has been reset to default No None D, M
Preventative Maintenance Alarm events 121 to 140
121 PM Alarm 1 has been triggered No
Service Tool D
122 PM Alarm 2 has been triggered No
Service Tool D
123 PM Alarm 3 has been triggered No Service Tool D
124 PM Alarm 4 has been triggered No Service Tool D
125 PM Alarm 5 has been triggered No Service Tool D
Programming Events 141 to 150
141 Invalid Conguration selected Yes Select a valid Conguration for the tool attached D, M
142 Two or more Congurations selected Yes Select only one Conguration D, M
147
The Auto Increment attempted to
select an invalid Conguration
No
Check the programming of the Auto Increment
function
D
Shutdown Events 151 to 170
151 Calibration Error No
Check tool cable. Reboot system, If error still occurs
call authorized Ingersoll Rand service center
D, M
152 Tool Motor Over Temperature Yes Allow tool to cool D, M
153 Heat Sink Over Temperature Yes Allow controller to cool D, M
154 Step Sequence Error No Check programming of Conguration D, M
156 MCE Watchdog Fault No
Reboot system, If error still occurs call authorized
Ingersoll Rand service center
D, M
157 Trigger Released No
Operator released trigger of tool before tightening
complete
D, M
158 Yield Override Failure No
Yield point of fastener reached before target
torque/angle
D, M
161
Average Prevailing Torque plus next
step Target Torque Exceeds next Step
High Limit
No None D, M
164 Failed to reach Target in Retorque No None D, M
166 No Bolt Fount / Cycle Timeout No Check fastener present in assembly D, M
Software Download Events 201 to 210
201 MCE rmware has been downloaded No None D, M
202 RICS Software has been downloaded No None D, M