Lincoln Electric SVM155-A Welder User Manual


 
Control
Transformer (T2)
X3
H2
H1
X1
F-10 F-10
TROUBLESHOOTING & REPAIR
MULTI-SOURCE
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TEST PROCEDURE
1. Disconnect main AC input power to the
machine.
2. Remove the Top and Right case side.
3. Locate the Control Transformer (T2) on the
left side of the input box (facing the back of
the machine). See Figure F.1.
4. Locate the Control Transformer primary
leads H1 & H2. See Wiring Diagram. See
Figure F.1.
5. Locate control transformer terminals X1 and
X3. See Figure F.1.
FIGURE F.1. CONTROL TRANSFORMER LOCATION & LEADS
CONTROL TRANSFORMER (T2) VOLTAGE TEST