Lincoln Electric SVM155-A Welder User Manual


 
F-56 F-56
TROUBLESHOOTING & REPAIR
MULTI-SOURCE
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
SCR BRIDGE / HEAT SINK ASSEMBLY REPLACEMENT PROCEDURE
13. Clear all leads and carefully maneuver
SCR bridge out of the right side of the
machine.
NOTE: Upon reassembly, apply a thin layer of
Lincoln Electric T12837 (Dow Corning
340) heat sink compound to all bolted
electrical connections on the alu-
minum heat sinks.
UPON REASSEMBLY, THE SCR BRIDGE
ASSEMBLY MUST BE ELECTRICALLY
ISOLATED FROM GROUND. MINIMUM
ACCEPTABLE RESISTANCE TO GROUND
IS 500K OHMS.
---------------------------------------------------
FIGURE F.28. Mounting Bolt
J1
J2
J3
J5
J6
J8
Firing Board
Control Board
J4
J7
Mounting Bolt
CAUTION