Lincoln Electric SVM185-A Welder User Manual


 
INSTALLATION
A-3 A-3
POWER FEED® 25M
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
SAFETY PRECAUTIONS
ELECTRIC SHOCK CAN KILL.
• Turn the input power OFF at the
welding power source before
installation or changing drive rolls
and/or guides.
• Do not touch electrically live parts.
• When inching with the gun trigger,
electrode and drive mechanism are
"hot" to work and ground and
could remain energized several
seconds after the gun trigger is
released.
• Welding power source must be connected to
system ground per the National Electrical Code
or any applicable local codes.
• Only qualified personnel should perform mainte-
nance work.
------------------------------------------------------------------------
LOCATION
For best wire feeding performance, place the POWER
FEED® 25M on a stable and dry surface. Keep the
wire feeder in a vertical position. Do not operate the
wire feeder on an angled surface of more than 15
degrees.
Do not submerge the POWER FEED® 25M.
The POWER FEED® 25M is rated IP23 and is suitable
for outdoor use.
The handle of the POWER FEED® 25M is intended
for moving the wire feeder about the work place only.
When suspending a wire feeder, insulate the hanging
device from the wire feeder enclosure.
HIGH FREQUENCY PROTECTION
Locate the POWER FEED® 25M away from radio con-
trolled machinery. The normal operation of the
POWER FEED® 25M may adversely affect the opera-
tion of RF controlled equipment, which may result in
bodily injury or damage to the equipment.
--------------------------------------------------------------------------
WARNING