Lincoln Electric SVM185-A Welder User Manual


 
OPERATION
B-30 B-30
POWER FEED® 25M
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
To set limits, press the desired memory button 1-6
and hold for 5 seconds. Release the memory button
when the LED begins to blink rapidly and the MSP4
displays "Memory X Set Limits" as shown below.
MSP4 DISPLAY
LIMITS
Limits allow the welder to adjust the welding procedure
only within a defined range.
Each user memory may have a different set of limits.
For example, memory 1 can be set to limit the WFS to
200 through 300 in/min, and memory 2 can be set to
limit the WFS to 275 through 310 in/min, while memo-
ry 3 may not have any WFS limits.
Parameters are always constrained by machine limits.
When memory limits are enabled, the parameter will
flash whenever an attempt is made to exceed the
memory limit value. The parameter will not flash if an
attempt is made to exceed the machine limit.
Machine limits are:
Parameter
Wire Feed
Speed
Voltage
Trim
Arc Control
Preflow
Start Time
Run-In WFS
Crater Time
Burnback Time
Postflow Time
Range
Weld mode dependent
and gear box ratio
dependent
Weld mode dependent
0.50 to 1.50
-10.0 to 10.0
0.0 to 2.5
0.0 to 10.0
Off, 50 to 150
0.0 to 10.0
0.00 to 0.25
0.0 to 10.0
Units
in/min
Volts
--
Weld mode dependent
Seconds
Seconds
in/min
Seconds
Seconds
Seconds
Limits may be set for:
• Wire Feed Speed/Amperage • Start Time
• Voltage/Trim • Burnback Time
• Arc Control • Crater Wire Feed Speed
• Preflow Time • Crater Voltage/Trim
• Run-In Speed • Crater Time
• Start Wire Feed Speed • Postflow Time
• Start Voltage/Trim
Weld modes cannot be selected through the Limits
Setup menu, and must be chosen and saved to mem-
ory before entering the Limits Setup Menu.
HOLD 2 SECONDS TO SAVE
PROCEDURE
MEMORY
A
GUN B
1
4
2
5
3
6
M
M
SET
SETUP
IR PORT
Set Limits
Memory 1
WAVEFORM CONTROL TECHNOLOGY
WELD MODE
ARC CONTROL
S
TART OPTIONS
E
ND OPTIONS
Set Limits:
Press 5
seconds