Lincoln Electric SVM185-A Welder User Manual


 
OPERATION
B-19 B-19
POWER FEED® 25M
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
PULSE
PULSE-ON-PULSE
FREQUENCY:
FREQ.MODULATION
(Low)-10.0 to
(High)+10.0
(Low)-10.0 to
(High)+10.0
DESCRIPTION
For Pulse -On-Pulse modes,
Arc controls changes the frequ-
ency modulation. The freque-
-ncy modulation controls the
spacing of the ripples in the
weld. Use low values for slow
travel speeds and wide welds,
and high values for fast travel
speeds and narrower welds.
For Pulse
modes, Arc Control
changes the pulsing frequency.
When the frequency changes,
the Power Wave system auto-
matically adjusts the back-
ground current to maintain a
similar heat input into the weld.
Low frequencies give more con-
trol over the puddle and high
frequencies minimize spatter.
PREFLOW TIME
0 - 10 seconds
RUN-IN WFS:
Off, 50 to150 in/min.
Start Procedure
DESCRIPTION
Adjusts the time that shielding
gas
flows
after
the trigger is
pulled
and
prior to feeding wire.
Run-in sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished.
The Start Procedure controls
the WFS. Trim at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.
EFFECT / RANGE
Postflow Time:
0 to 10 seconds
Burnback: 0 to .25
Seconds
Crater Procedure
FUNCTION
Adjusts the time that shielding
gas flows after the welding out-
put turns off.
The burnback time is the
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
Crater Procedure controls the
WFS and Trim for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.
ELECTRODE AND GAS
ALUMINUM 4043
ALUMINUM 4043
ALUMINUM 5356
ALUMINUM 5356
Ar
Ar
Ar
Ar
WIRE SIZE
0.035 3/64 1/16
149 72 74
98 99 100
152 76 78
101 102 103
WELD MODES
START OPTIONS
END OPTIONS
ARC CONTROL
Aluminum
3/64"
SET
SETUP
IR PORT
4043 Pulse Ar
WAVEFORM CONTROL TECHNOLOGY
WELD MODE
ARC CONTROL
72
START OPTIONS
END OPTIONS
220
1.06
WFS AMPS
VOLTS TRIM
Less
Deposition
S
horter
Arc
Longer
Arc
More
Deposition
Aluminum Pulse and Pulse-On-Pulse (Synergic) Weld Display
MSP4 OPERATION