Lincoln Electric SVM185-A Welder User Manual


 
FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The wire feed speed is consistent
and adjustable, but runs at the
wrong speed.
1. The DIP switch on the wire drive
unit may not be set for the correct
gear ratio. See the Installation
section of this manual.
1. The feed head control board
may be faulty.
2. The wrong gear may be installed.
The unit shuts off while welding or
attempting to weld. The STATUS
LED is alternating between red and
green every second. The unit tries
to recover after 30 seconds and
may repeat sequence.
1. The drive motor may be over-
loaded due to a mechanical
restriction in the wire feeding
path. See Operation section of
this manual.
1. If there are no restrictions in the
wire feeding path, the drive
motor or gear box may be faulty.
2. The feed head control board
may be faulty.
TROUBLESHOOTING AND REPAIR