Lincoln Electric SVM185-A Welder User Manual


 
OPERATION
B-31 B-31
POWER FEED® 25M
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Four items show on the MSP4 panel.
• Memory Value
• High Limit
• Low Limit
• Parameter Name
One of these items will flash to indicate which item will
change when the MSP4 encoder is rotated. Press the
right button on the MSP4 panel to select the item to
change.
The Limits Setup menu shows a list of all parameters
available for the weld mode stored in the memory cho-
sen. For example, if limits are being set for a stick
(SMAW) mode, parameters such as Run-in WFS and
Postflow will not appear.
To lock a parameter to a specific value that cannot
be changed, set the high and low limits to the same
value.
SET
SETUP
HiHi
LoLo
IR PORT
Weld WFS
= 200
= 180
WAVEFORM CONTROL TECHNOLOGY
WELD MODE
ARC CONTROL
START OPTIONS
END OPTIONS
200
SET
S
ETUP
HiHi
LoLo
IR PORT
Weld WFS
= 200
= 180
W
AVEFORM CONTROL TECHNOLOGY
WELD MODE
A
RC CONTROL
START OPTIONS
END OPTIONS
200
Memory Value
Parameter Name
High Limit
Low Limit
The memory value must always be less than or equal
to the high limit, and greater than or equal to the low
limit.
After setting limits, press the memory button with the
flashing LED. The MSP4 will ask to save or discard the
limit changes just made. Press the left MSP4 for but-
ton (YES) to save and enable the limits and exit. Press
the right MSP4 button (NO) to exit and leave limits
unchanged.
Enabling/Disabling Limits
Limits for each memory may be enabled or disabled
by pressing and hold the appropriate memory button
for 10 seconds. Release the memory button when
the MSP4 display shows the following:
Press the left MSP4 button (YES) to enable limits or
the right MSP4 button (NO) to disable limits. Disabling
limits does not change any limits values that may
have been previously set.
H
OLD 2 SECONDS TO SAVE
PROCEDURE
MEMORY
A
GUN B
1
4
2
5
3
6
M
M
Enable/Disable
Limits: Press
10 seconds
Rotate to
Change
Value.
Press to
select item
to change.
S
ET
S
ETUP
IR PORT
Enable/Disable
Memory 1
Limits
WAVEFORM CONTROL TECHNOLOGY
WELD MODE
ARC CONTROL
START OPTIONS
E
ND OPTIONS
SET
SETUP
IR PORT
Yes No
Enable
Limits?
WAVEFORM CONTROL TECHNOLOGY
WELD MODE
ARC CONTROL
START OPTIONS
END OPTIONS