Accessing Storage Devices
6-00025-01 Rev A Library List 2-7
The Scalar 1000 is taken OFFLINE-NOT READY perhaps
because a door is open. The AMU automatically stops polling
the AML/S whenever the library is offline.
Step 1. Close the door, or take the appropriate steps to get
the library to the ONLINE READY state.
Step 2. Inventory the Scalar 1000 to ensure that only valid
database information is uploaded.
Although the Scalar 1000 becomes operational, the
AMU cannot initiate polling.
Step 3. Run the HOME command from the AMU to establish
communication with the Scalar 1000.
Step 4. Activate polling by running the STATUS command
with the appropriate option to select the correct
robot.
After the Scalar 1000 is online, the database is automatically
uploaded.
Note
If the Scalar 1000 is not inventoried in Step 1., the AMU database
will contain invalid status information. Consequently, you must
erase the AMU database and then recreate the database to clear
this condition. (When changing the AMU configuration or database,
stop the communication between the AMU and the Scalar 1000.)