ADIC 6-00025-01 Tool Storage User Manual


 
Accessing Storage Devices
6-00025-01 Rev A Library List 2-37
Power Outage
If the IBM 3494 experiences a temporary power
outage, but the server has not gone down, the
following error message may display in syslog.
If it does not appear, it will appear after you enter the
stop command in Step 2:
Step 1. Enter the following to recycle the Library Manager
Control Point Daemon (LMCPD) after power is
restored to the hardware:
After the lmcpd daemon starts, the following
message appears in syslog:
Step 2. Rerun the AMASS command, if one was in
progress.
If you were using the bulkinlet command when
the library lost power:
- Remove the media from the port
- Close the port
Jukebox 1 LMCPD Server is not
active, please start.
# sh /etc/init.d/ibm3494 stop
# sh /etc/init.d/ibm3494 start
IBM Automated Tape Library Daemon
Loaded